Variable frequency driveGK3000 series Variable Frequency Drives (VFD) are manufactured by Shenzhen Gozuk Co., Limited in China, the VFD adopts advanced speed sensorless vector control technology to offer excellent control performance, enhances operation reliability and environment adaptability.

GK3000 VFD Capacity:
1/2 hp - 5 hp for single phase to three phase 220V
1 hp - 500 hp for three phase 380V
As one of the top VFD manufacturers in China, Gozuk drives are widely used in various applications, such as fans and pumps, industry washing machines, injection molding machines, textile machines, grinding machines, ball mill machines, HVAC system, constant pressure water supply system and lots of other applications which need VFD to vary motor speed.

Beyond China domestic market, Gozuk VFDs have been export to India, Pakistan, Turkey, Philippines, Thailand, Australia, South Africa, and much more countries.

GK 3000 series Variable Frequency Drive General Specifications
Items Specifications
Input Voltage / Frequency Single phase 220V, three phase 200V, three phase 380V; 50Hz/60Hz
Range Voltage: ±20% voltage unbalance rate: <3%; frequency: ±25%
Output Rated voltage 0~200V/220V/380V
Frequency range 0Hz~400Hz
Frequency resolution 0.01Hz
Overload ability 150% rated current for 1 minute, 180% rated current for3 seconds
Control function Modulation modes Optimized space voltage vector SVPWM modulation
Control mode Sensorless vector control (with optimal low frequency, dead time compensation)
Frequency precision Digital setting: The highest frequency ×± 0.01%
Analog setting: The highest frequency ±0.2%
Frequency resolution Digital setting: 0.01Hz
Analog setting: The highest frequency× 0.1%
Start frequency 0.40Hz~20.00Hz
Torque boost Auto torque boost, manual torque boost 0.1%~30.0%
V/F curve Five ways: constant torque V/F curve, 1 kind of user defined V/F curve, 3 kinds of down torque curve(2.0/1.7/1.2 times the power)
Acc./Dec. curve Two ways: linear Acc./Dec., S-curve Acc./Dec.;
7 kinds of Acc./Dec. time, time unit (minute/second) optional, max. Time: 6000 minutes.
DC braking DC braking start frequency: 0~15.00Hz
braking time: 0~60.0 seconds
braking current: 0~80%
Energy consuming braking Energy consuming braking unit built-in, external braking resistor can be
Jog running Jog frequency range: 0.1Hz~50.00Hz, JOG Acc./Dec. time: 0.1~60.0s
PI built-in Easily constitute a close loop control system
Multi-stage speed running Multi-stage speed running available through built-in PLC or control terminals
Textile swing frequency Swing frequency available with preset and center frequency adjustable
Auto voltage regulation When the grid voltage changes, to maintain constant output voltage
Auto energy saving running Saving energy by auto optimizing V/F curve according to the load
Auto current limiting Auto current limiting to prevent frequent over current fault trip
Fixed-length control VFD stops when reaches the preset length
Communication RS485 standard communication port available, support MODBUS communication protocol of ASCII and RTU, master-slave multi-machine interaction function available
Running function Running command channel Control panel, control terminal, serial port 3 channels switchable
Frequency setting channel Control panel potentiometer: ▲,▼control panel keys, function code digital, serial port, terminal up/down, analog voltage, analog current, pulse, combination setting, all channels switchable
Switch input channel FWD/REV command: 8 channels programmable switch inputs, 35 kinds of function can be set separately
Analog input channel 4~20mA and 0-10V 2 optional analog inputs
Analog output channel 4~20mA or 0~10V optional, setting frequency and output frequency , etc. can be output
Switch/pulse output channel Programmable open collector output: relay output, 0~20KHz pulse output.
Control panel LED digital display Display setting frequency, output voltage, output current, etc.
External meter display Display output frequency, output current, output voltage, etc.
Key lock All the keys can be locked
Parameter copy Function code parameters are able to be copied between VFDs when use remote control panel.
Protection function Over current protection, over voltage protection, under voltage protection, overheating protection, over load protection, etc.
Optional parts Braking unit, remote control panel, cable, panel mounting feet, etc.
Environment Environment Indoors, free from direct sunlight, dust, corrosive gas, oil mist, steam, water dropper salt, etc.
Altitude Lower than 1000m (derating is necessary above 1000m)
Ambient temperature -10℃~+40℃
Humidity <90%RH, no condensation
Vibration Lower than 5.9m/s (0.6g)
Storage temperature -20℃~+60℃
Structure Protection level IP20 (In the selection of state display unit or the keyboard state)
Cooling Forced air cooling
VFD Installation Wall mounted

Contact us now to get a low cost VFD from manufacturer directly, fast shipping from China to global countries.
Category
Featured Articles
Variable Frequency Drive Sizing Variable Frequency Drive SizingBefore selecting the size of a variable frequency drive (VFD), it is necessary to generally know the working environment, the ...
Single VFD for Multiple Motors Single VFD for Multiple MotorsA single variable frequency drive (VFD) may control 2 or 3 motors at a time, multiple motors control is usually done because of ...
PWM Variable Frequency Drive ... PWM Variable Frequency Drive CharacteristicsPulse Width Modulation (PWM) voltage source variable frequency drives (VFD) presently comprehend the most used equipments to feed ...
Variable frequency drive for water ... Variable frequency drive for water pumpsQuantifying the energy efficiency of pump units across markets is a tough task: These units mostly consist of rotodynamic pumps ...
Variable Frequency Drive Basic Safety ... Variable Frequency Drive Basic Safety GuidelinesThis paper provides guidelines on functional safety considerations when selecting and integrating a variable frequency drive ...
service
Variable Frequency Drives control AC motor for energy savings by adjustable speed, for short VFD, also named variable speed drives and frequency inverter.